12
RP 210 Press Tool
RP 210 Diagnostic Codes
LED Status Description Icon
Green
Glows Tool ON.
Blinks Out of acceptable voltage range.
— Replace battery with a fully charged battery.
Red Blinks Attachment mounting pin not fully engaged. Insert pin.
Glows If only red light is ON, Out of temperature range 15°F (-10°C) to 122°F (50°C).
Yellow Blinks Service indicator after 30,000 cycles. NOTE: Tool will lock after 32,000 cycles.
Glows Machine is locked – Service after 32,000 cycles or after a malfunction.
SYMPTOM POSSIBLE REASONS SOLUTION
Yellow LED glows con-
tinuously and tool will
not begin press cycle
when trigger switch is
depressed.
Red LED blinks repeated-
ly and tool will not begin
press cycle when trigger
switch is depressed.
Yellow LED glows when
tool is turned ON.
Jaws are locked onto
fitting.
The pressed connections
produced are not com-
plete.
Troubleshooting
(Continued)
Scheduled maintenance/recalibration is manda-
tory after 32,000 presses. Tool is “locked” and
will not function until tool is serviced.
Attachment mounting pin not fully closed.
Tool malfunction detected.
Press was not successfully completed.
Used wrong jaws for the tube size or material.
The tool was not square to the tube.
Jaw contour was not aligned with the fitting contour.
Tool is in need of repair.
Insert attachment mounting pin to the fully closed
position.
Remove and reinsert fully charged battery. Be sure
to repress fitting. If LED’s continue to glow, contact
Ridge Tool Company, Technical Service Depart-
ment at (800) 519-3456 for nearest Authorized
Service outlet.
Push pressure release valve to remove jaws from fit-
ting. Inspect and repress fitting.
Install the correct jaws.
Redo the joint with new fitting and new tube.
Make sure that the tool is square to the tube.
Redo the joint with new tube and new fitting.
Make sure the jaw contour is aligned with the
fitting contour.
Figure 12 – LED Diagnostic Codes